Skip to content

Errors and close codes

When a request fails, the server answers with an error frame that carries the request’s id:

{
"id": 6,
"type": "error",
"code": "not_authorized",
"message": "not authorized to publish to 'news/today'"
}

Match on code, never on message. locked_out and rate_limited also carry retry_after in seconds. Later releases may add codes, so treat one you don’t recognise as internal.

The connection stays open after these.

Code Meaning
bad_request The frame is malformed, or a field is out of range
invalid_topic A bad topic name, or a malformed pattern
not_authorized The account may not use that topic that way
payload_too_large The payload is over max_payload_bytes
rate_limited Publishing or registering too fast
invalid_credentials Login failed
locked_out Too many failed logins
registration_failed Registration was refused
storage_unavailable The server couldn’t read or write its log
forbidden An admin request from a non-admin
user_not_found No such account
user_exists That username is taken
topic_not_found Nothing was ever published to that topic

invalid_credentials and registration_failed never say whether a username exists. A confirmed publish that got storage_unavailable was not stored, so retry it with the same message_id.

The server sends the error, then closes with the code shown.

Code Close Why
unauthenticated 4002 A request arrived before auth
auth_failed 4001 The token is invalid, expired or revoked
auth_failed 4009 The token’s account is disabled or deleted
invalid_session_id 4001 The session_id is empty, too long or has control characters
unsupported_protocol 4006 The server only speaks protocol 1
session_unavailable 4007 The session store was down
internal 1011 Something failed inside the server

Two exceptions stay open: a second auth on a live connection with another user’s token gets auth_failed and keeps its original token, and an internal answering an admin request fails only that request.

Code Reason Reconnect?
1001 going_away Yes, with backoff. The server is shutting down.
1009 message_too_big Yes, but don’t resend that frame.
1011 internal_error Yes, with backoff.
1013 try_again_later Yes, with backoff. The server is at its connection limit.
4001 auth_failed No. Log in again first.
4002 unauthenticated Yes, and send auth first.
4003 session_taken_over No. Another connection took the durable session.
4004 token_expired Yes, after logging in again.
4005 idle_timeout Yes. Nothing arrived from the client for 90 seconds (the default).
4006 unsupported_protocol No.
4007 session_unavailable Yes, with backoff.
4008 slow_consumer Yes. The client fell too far behind reading.
4009 account_disabled No.

The client libraries follow this table for you, with one difference: after 4004 they only reconnect if they were given a password, since a bare token can’t be renewed.